Request Quote
Electronic G2Electronic G3Electronic G4Electronic G5Trace Analysis Chemicals

Trace Grade Hydrochloric Acid

HCl · CAS 7647-01-0

Trace Grade Hydrochloric Acid considered for ICP-MS preparation, analyte stabilisation, digestion chemistry. Selection begins with the application, critical limits, destination, pack and qualification plan.

A common starting point

ICP-MS preparation

Molecular weight

36.46 g/mol

Boiling point

110 °C (azeotrope)

Density

1.18 g/mL (37%)

High-purity optionsBatch documentationFlexible packaging review
Hydrochloric Acid manufacturing, filling and industrial supply environment

Product identity

CAS number
7647-01-0
Formula
HCl
Boiling point
110 °C (azeotrope)
Density
1.18 g/mL (37%)

Product overview

A product route built around the application

Hydrochloric Acid is considered for processes that need a consistent material, controlled critical impurities and a supply format that can move from qualification to routine use. The grade should be selected against the actual process—not a generic purity claim.

01

High-purity options

Compare listed grades and current product-specific limits.

02

Controlled attributes

Focus testing on the impurities and performance risks that matter.

03

Supply planning

Align sample, production pack, forecast and document route early.

Purification and controlled manufacturing route for Hydrochloric Acid

Application fit

Qualify Trace Grade Hydrochloric Acid around the process

The product name begins the discussion. Critical attributes, test methods, packaging and routine supply conditions determine whether a candidate is useful.

01

ICP-MS preparation

Review the current specification and representative sample against the actual process and qualified baseline.

02

analyte stabilisation

Review the current specification and representative sample against the actual process and qualified baseline.

03

digestion chemistry

Review the current specification and representative sample against the actual process and qualified baseline.

Before you specify

A better enquiry starts with four answers

A higher grade is not automatically the better choice. The useful option fits the process, analytical method, packaging route and qualification plan without adding controls the application does not need.

01

What role does the material perform in the process?

02

Which limits and methods control customer acceptance?

03

What sample and production pack represent routine use?

04

Which destination, documents, annual demand and timing apply?

Specification data

Compare the listed grade columns

This table is an indicative product overview for initial screening. Confirm the current controlled specification, test methods, reporting limits and available lot documentation before qualification or purchase.

ParameterTest methodUnitG4G5
AssayTitration%36.0–38.036.0–38.0
Total MetalsICP-MSppb ea.≤0.5<0.1
Fe (Iron)ICP-MSppb≤0.2<0.05
Free ChlorineTitrationppm≤0.5≤0.1
Sulfate (SO₄²⁻)ICppb≤50≤10

Website values do not replace a signed sales specification. The agreed specification and lot-specific Certificate of Analysis govern supplied material.

Electronic grade context

Use the grade scale as a first comparison

SEMI C1 describes liquid-chemical grades and analytical procedures. A grade name helps organise a discussion; your process specification still decides which limits and methods are acceptable.

Electronic Grade Purity Comparison — SEMI C1 StandardG1 → G5
GradePurity (GC)Metals (ICP)ParticlesWater (KF)Process Node
G2
≥99.9%
≤10 ppb≤100/mL≤50 ppm≥180nm Mature Node
G3
≥99.99%
≤2 ppb≤20/mL≤20 ppm45–180nm
G4
≥99.999%
≤0.5 ppb≤10/mL≤10 ppm7–45nm
G5
≥99.9999%
<0.1 ppb≤5/mL≤5 ppm<7nm / EUV / Marangoni

All grades tested by ICP-MS (28 elements), in-line LPC (ISO Class 3 fill), and Karl Fischer titration. G5 = SEMI C1 Tier D. Full CoA per lot.  Request CoA template →

Where this product is used

Application routes for Hydrochloric Acid

These examples help with discovery. They are not claims of universal suitability; material compatibility, process performance and the controlled specification still need review.

Hydrochloric Acid industrial and analytical application environment

Semiconductor & electronics

  • RCA SC-2 (HPM) metal ion removal
  • Gold (Au) selective etching
  • Al/Ti metal removal
  • Post-ion-implant metal clean
  • Compound semiconductor (GaAs, InP) surface preparation

Laboratory & analytical

  • pH adjustment
  • ion chromatography eluent
  • gravimetric analysis

Industrial & other

  • PCB copper etching
  • steel pickling
  • food processing (E507)

Representative application cases

A practical evidence route for Hydrochloric Acid

These are illustrative composite qualification scenarios, not named customer claims. Exact methods, limits and acceptance decisions belong to the customer’s controlled process.

CASE 01

Method-blank investigation

An analytical laboratory checks whether Hydrochloric Acid (Electronic Grade) contributes to variability near its working reporting range.

Evidence route

The candidate lot is run through the laboratory’s actual preparation method; supplier data supports but does not replace local blank trending.

CASE 02

Multi-site reagent alignment

European and US laboratories compare Hydrochloric Acid (Electronic Grade) for a shared analytical workflow.

Evidence route

Pack, sampling, storage, element panel and acceptance checks are aligned, followed by verification at each site.

Purification, filtration, testing and clean filling for Hydrochloric Acid

Manufacturing advantage

A controlled route from purification to final filling

The supply route for Hydrochloric Acid connects incoming-material review, product-specific treatment, controlled transfer, testing, filling and lot documentation. Exact equipment and controls depend on the qualified product and grade.

01

Purification

Product-specific separation or treatment route.

02

Filtration

Compatible filtration and controlled transfer.

03

Testing

Release against the agreed specification.

04

Clean filling

Pack, closure and lot identification review.

Explore manufacturing →

Quality assurance & documentation

Evidence your quality team can review

Documents are matched to the supplied product, grade, lot and destination. The links below request the current controlled version; they are not static files with uncertain revision status.

Quality testing and controlled documentation for Hydrochloric Acid

Packaging options

Choose the pack with the handling route in mind

Availability varies by grade and destination. Confirm container material, closure, headspace, connection, minimum order, dangerous-goods route and qualification-lot needs.

01

Qualification & laboratory packs

For evaluation, method work and lower-volume routine use.

1 L5 L
02

Drums & production packs

For regular production consumption and controlled dispensing.

20 L200 L
03

IBC & bulk routes

For higher-volume programmes after site, grade and logistics review.

Confirm by grade

Technical resources

Continue the technical review

Use application notes for context, then confirm current product documents before qualification.

Knowledge centre →

Start a product review

Need a reliable supply route for Hydrochloric Acid?