Home
Pharma GradeAnalytical ReagentIndustrialLaboratory & Analytical Solvents

Petroleum Ether

C₅–C₈ alkanes · CAS 8032-32-4

Analytical and pharmaceutical grade petroleum ether for Soxhlet fat/lipid extraction, column and TLC chromatography, and non-polar analyte sample preparation. Available in 30–60 °C, 60–90 °C, and 90–120 °C boiling fractions.

Substrate hydrocarbon degreasingwafer organic contamination removal

Molecular Weight

~72–114 g/mol

Boiling Point

30–150 °C (fractions)

Density

0.63–0.76 g/mL

Molecular Formula

C₅–C₈ alkanes
CAS Number8032-32-4
Boiling Point30–150 °C (fractions)
Density0.63–0.76 g/mL
MW~72–114 g/mol

Available Grades

PHARMAARINDUSTRIAL

Analytical Specification

Analytical Specification Table

All values represent maximum allowable limits unless noted ≥. A lot-specific Certificate of Analysis (CoA) with ICP-MS, LPC, and GC data is issued for every shipment. Full data packages available on request.

ParameterTest MethodUnitPharmaAR
Distillation RangeASTM D86°CStated range ±2Stated range ±2
Residue on EvaporationGravimetricppm≤2≤5
Sulfur ContentCombustionppm≤0.5≤1

★ G5 = SEMI C1 Tier D (6N grade). All metal values by ICP-MS. Particle counts by in-line LPC during ISO Class 3 fill. CoA available on request.

Grade Comparison

G1 → G5 Purity Scale

Select the grade that matches your process node and contamination budget. Every grade is available from PureTech with full lot CoA and ICP-MS data.

Electronic Grade Purity Comparison — SEMI C1 StandardG1 → G5
GradePurity (GC)Metals (ICP)ParticlesWater (KF)Process Node
G1
≥99.0%
≤50 ppb≤500/mL≤500 ppmPCB / Display / Solar
G2
≥99.9%
≤10 ppb≤100/mL≤50 ppm≥180nm Mature Node
G3
≥99.99%
≤2 ppb≤20/mL≤20 ppm45–180nm
G4
≥99.999%
≤0.5 ppb≤10/mL≤10 ppm7–45nm
G5
≥99.9999%
<0.1 ppb≤5/mL≤5 ppm<7nm / EUV / Marangoni

All grades tested by ICP-MS (28 elements), in-line LPC (ISO Class 3 fill), and Karl Fischer titration. G5 = SEMI C1 Tier D. Full CoA per lot.  Request CoA template →

Application Areas

Where Petroleum Ether Is Used

Semiconductor Process

  • Substrate hydrocarbon degreasing
  • wafer organic contamination removal

Laboratory & Analytical

  • Soxhlet fat & lipid extraction (ISO 6492)
  • TLC development solvent
  • normal-phase column chromatography
  • non-polar metabolite extraction

Industrial & Other

  • Edible oil & fats extraction
  • rubber & polymer processing
  • adhesive formulation

Packaging & Supply

Available Container Formats

500 mL
2.5 L
5 L
25 L

Get Started

Request a Sample or
Technical Quote

Our application engineers respond with full CoA data, ICP-MS reports, and supply chain details within one business day.